Posted: Thu Feb 10, 2005 10:01 pm    Post subject: Oscilloscope HP 1740A, how to fix it? Reply with quote

-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

Hello,
i have a HP 1740A. Unfortunately it stopped working while it was showing
the 1V calibration signal and i was changing the VOLT/DIV scale to
increase its size on the screen.
The screen stopped showing the signal and also i noticed that it is not
anymore illuminated (changing the scale illumination doesn't change
anything).
I opened it and i can see that the cathodic tube shows an orange light
and its brightness changes when i change the "scale illumination" but
the screen keeps being "black" [without illumination].

Any idea about what might cause this?

I checked all the Test Points where i could read the supposed voltage
and all seems fine, unfortunately i do not have a service manual (i
believe this is how you call those manuals for reparation purposes) so i
could not test many other test points.

Does anyone have the service manual for this oscilloscope and could send
it to me by email?

Thank you,
~ Luca

P.S.: Sorry for my bad english.
-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.2.4 (GNU/Linux)
Comment: Using GnuPG with MultiZilla - http://enigmail.mozdev.org

iD8DBQFCC4VLliez+Z59f3URAlttAKCbRjjiWbBq0yANVAPERav6YU6n0ACcC5DX
k2/f33krr5si9OeM4RD7tRY=
=wBxT
-----END PGP SIGNATURE-----

Back to top
Jim Yanik
Guest





Posted: Fri Feb 11, 2005 6:11 am    Post subject: Re: Oscilloscope HP 1740A, how to fix it? Reply with quote

"Luca T." <lucat@despammed.com> wrote in
news:371eqdF582vqjU1@individual.net:

Quote:
-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

Hello,
i have a HP 1740A. Unfortunately it stopped working while it was showing
the 1V calibration signal and i was changing the VOLT/DIV scale to
increase its size on the screen.
The screen stopped showing the signal and also i noticed that it is not
anymore illuminated (changing the scale illumination doesn't change
anything).
I opened it and i can see that the cathodic tube shows an orange light
and its brightness changes when i change the "scale illumination" but
the screen keeps being "black" [without illumination].

Any idea about what might cause this?

I checked all the Test Points where i could read the supposed voltage
and all seems fine, unfortunately i do not have a service manual (i
believe this is how you call those manuals for reparation purposes) so i
could not test many other test points.

Does anyone have the service manual for this oscilloscope and could send
it to me by email?

Thank you,
~ Luca

P.S.: Sorry for my bad english.

Basic modules of any scope;
1. power supplies;*first to be checked*
2. vertical deflection circuits
3. triggering
4. sweep(horizontal) deflection
5. CRT unblanking and intensity control

If you can access the vertical and horizontal deflection CRT pins,you can
short them (vert-vert,H to H) and see if you get a trace or spot on screen.
If so,then you have a problem in the corresponding circuit.(short verticals
and get trace=bad vertical amp).short horizontal pins and get spot=bad
horiz or triggering)

--
Jim Yanik
jyanik
at
kua.net
Back to top
Luca T.
Guest





Posted: Sat Feb 12, 2005 2:58 pm    Post subject: Re: Oscilloscope HP 1740A, how to fix it? Reply with quote

-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

Jim Yanik wrote:

| Basic modules of any scope;
| 1. power supplies;*first to be checked*

This seems to work, at least the values that i could read on some
test-points were correct, unfortunately i do not have a service manual
or anything that would tell me what the correct voltages of other
test-points are (i could only test the ones where their supposed voltage
values is written on the board).

| 2. vertical deflection circuits
| 3. triggering
| 4. sweep(horizontal) deflection
| 5. CRT unblanking and intensity control
|

Sigh, i am absolutely ignorant about oscilloscopes and without a manual
to tell me exactly what to do i am lost :(

| If you can access the vertical and horizontal deflection CRT pins,you can
| short them (vert-vert,H to H) and see if you get a trace or spot on
screen.
| If so,then you have a problem in the corresponding circuit.(short
verticals
| and get trace=bad vertical amp).short horizontal pins and get spot=bad
| horiz or triggering)
|

I wish i knew where those pins are, i do not really feel like to
short-circuit random pins. Sigh... anyone knows where i could find the
service manual of this oscilloscope without having to buy a copy?

Thank you for your answers,
~ Luca
-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.2.4 (GNU/Linux)
Comment: Using GnuPG with MultiZilla - http://enigmail.mozdev.org

iD8DBQFCDcU2liez+Z59f3URAnvmAJ9bFBFQODvZBzuHFGPlxjrGbCr0qwCfaPi7
l6TuOB7WgvKu+axWh6mk91I=
=lsOt
-----END PGP SIGNATURE-----

Back to top
 
Post new topic   Reply to topic    Electronics Forum Index -> Repair All times are GMT
Page 1 of 1

 
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum



Home & Living New Topics
Contact Us
Powered by phpBB