| Author |
Message |
rubens
Guest
|
Posted:
Mon Feb 14, 2005 6:55 pm Post subject:
tektronix 2465B test 04 fail 10 |
|
|
my scope show test 04 fail 10
J'm looking for schematic for this scope ( J have manual without diagram
schematic )
probably scope need calibration or someting is damaged with memory
( sorry for my english )
Best regards from Poland
|
|
| Back to top |
|
 |
Jim Yanik
Guest
|
Posted:
Mon Feb 14, 2005 11:06 pm Post subject:
Re: tektronix 2465B test 04 fail 10 |
|
|
"rubens" <rafalparzyszek@poczta.onet.pl> wrote in
news:d45c64a91df95d6bc773438865afbddf@localhost.talkaboutelectronicequipmen
t.com:
| Quote: | my scope show test 04 fail 10
J'm looking for schematic for this scope ( J have manual without diagram
schematic )
probably scope need calibration or someting is damaged with memory
( sorry for my english )
Best regards from Poland
|
Bad EAROM perhaps.That means you may have lost your calibration constants
that the microprocessor loads into registers throughout the scope to set
gains,timing speeds,etc.
--
Jim Yanik
jyanik
at
kua.net |
|
| Back to top |
|
 |
tekamn
Guest
|
Posted:
Tue Feb 15, 2005 2:51 pm Post subject:
Re: tektronix 2465B test 04 fail 10 |
|
|
Jim Yanik wrote:
| Quote: | "rubens" <rafalparzyszek@poczta.onet.pl> wrote in
news:d45c64a91df95d6bc773438865afbddf@localhost.talkaboutelectronicequipmen
t.com:
my scope show test 04 fail 10
J'm looking for schematic for this scope ( J have manual without
diagram
schematic )
probably scope need calibration or someting is damaged with memory
( sorry for my english )
Best regards from Poland
Bad EAROM perhaps.That means you may have lost your calibration
constants
that the microprocessor loads into registers throughout the scope to
set
gains,timing speeds,etc.
--
Jim Yanik
jyanik
at
kua.net
|
04 fail 10 means bad checksum, bit 4 set. Or in other words: He has to
run through the cal process.
The OP can download the service manual for free from
www.teknetelectronics.com
This manual includes all the schematics and calibration process steps.
Good luck!
hth,
Andreas
|
|
| Back to top |
|
 |
rubens
Guest
|
Posted:
Tue Feb 15, 2005 7:50 pm Post subject:
Re: tektronix 2465B test 04 fail 10 |
|
|
Thank's for answers.
I will try to calibrate scope .
If it will not set then EAROM is bad.
Where is possible it to buy EAROM? |
|
| Back to top |
|
 |
Jim Yanik
Guest
|
Posted:
Wed Feb 16, 2005 6:10 am Post subject:
Re: tektronix 2465B test 04 fail 10 |
|
|
"tekamn" <and7@bigfoot.com> wrote in
news:1108457507.820534.233620@c13g2000cwb.googlegroups.com:
| Quote: |
Jim Yanik wrote:
"rubens" <rafalparzyszek@poczta.onet.pl> wrote in
news:d45c64a91df95d6bc773438865afbddf@localhost.talkaboutelectronicequi
pmen
t.com:
my scope show test 04 fail 10
J'm looking for schematic for this scope ( J have manual without
diagram
schematic )
probably scope need calibration or someting is damaged with memory
( sorry for my english )
Best regards from Poland
Bad EAROM perhaps.That means you may have lost your calibration
constants
that the microprocessor loads into registers throughout the scope to
set
gains,timing speeds,etc.
--
Jim Yanik
jyanik
at
kua.net
04 fail 10 means bad checksum, bit 4 set. Or in other words: He has to
run through the cal process.
The OP can download the service manual for free from
www.teknetelectronics.com
This manual includes all the schematics and calibration process steps.
Good luck!
hth,
Andreas
|
If he recals,and then gets another fail message,then the EAROM is bad;it's
not retaining the data. We used to replace a lot of EAROMs at TEK while I
was there.
--
Jim Yanik
jyanik
at
kua.net |
|
| Back to top |
|
 |
rubens
Guest
|
Posted:
Tue Feb 22, 2005 9:27 pm Post subject:
Re: tektronix 2465B test 04 fail 10 |
|
|
This manual ( www.teknetelectronics.com) it's without the schematics :(
Can these schemes has anyone? |
|
| Back to top |
|
 |
|
|
|
|